My Quote My Quote

PULSE VACUUM LARGE HA-6000 SERIES

Pulse Vacuum Large Horizontal Autoclave/Steam Sterilizer HA-6000 Series basic 250L, 360L, 600L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use. The HA-6000 comes with door sealing including pneumatic sealing both doors interlocking is strictly in accordance with the GSSD required. The machine has maximum sterilization pressure of 105 to 134°C with overload pressure protection.  Adopt piping system with the reliable pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, related spares are all according to the sanitation standard. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement.

PULSE VACUUM LARGE HA-6000 SERIES

Pulse Vacuum Large Horizontal Autoclave/Steam Sterilizer HA-6000 Series basic 250L, 360L, 600L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use. The HA-6000 comes with door sealing including pneumatic sealing both doors interlocking is strictly in accordance with the GSSD required. The machine has maximum sterilization pressure of 105 to 134°C with overload pressure protection.  Adopt piping system with the reliable pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, related spares are all according to the sanitation standard. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement.

Full Description

Pulse Vacuum Large Horizontal Autoclave/Steam Sterilizer HA-6000 Series basic 250L, 360L, 600L horizontal autoclave suitable for sterilizing heavy load and instruments for medical and laboratory use. The HA-6000 comes with door sealing including pneumatic sealing both doors interlocking is strictly in accordance with the GSSD required. The machine has maximum sterilization pressure of 105 to 134°C with overload pressure protection.  Adopt piping system with the reliable pneumatic angle type valve, water ring pump and 0.22µm high efficiency sterile medical grade filters, the pipe clamp adopts the quick connectors, related spares are all according to the sanitation standard. Built-in efficient steam generator, microcomputer temperature control, especially designed for bulk volume and highest flexibility in processing requirement.

Loading...
We can't find products matching the selection.